Test log

Test log for mcstas_svn_2013-04-29_linux.log

(Complete log available here)
(Output data available here)
[FAILED] ILL_H10_IN8_4 (accuracy off by 49 %)
[FAILED] ILL_H10_IN8_5 (accuracy off by 49 %)
[FAILED] ILL_H53_IN14_70 (accuracy off by 24 %)
[FAILED] HZB_NEAT_71 (accuracy off by 99 %)
[FAILED] HZB_NEAT_72 (accuracy off by 98 %)
[FAILED] ILL_H25_IN22_78 (accuracy off by 28 %)
[FAILED] templateDIFF_79 (accuracy off by 70 %)
[FAILED] Test_Sources_37 (compilation/execution)
[FAILED] Samples_Incoherent_41 (compilation/execution)
[FAILED] ISIS_test_48 (compilation/execution)
[FAILED] ISIS_GEM_62 (compilation/execution)
[FAILED] ISIS_HET_102 (compilation/execution)
[OK]     ILL_H113_1 (accuracy, 2 %)
[OK]     ILL_H13_IN20_2 (accuracy, 4 %)
[OK]     ILL_H13_IN20_3 (accuracy, 9 %)
[OK]     Samples_Phonon_6 (accuracy, 1 %)
[OK]     ILL_H22_D1A_7 (accuracy, 9 %)
[OK]     ILL_H15_IN6_8 (accuracy, 2 %)
[OK]     ILL_H22_VIVALDI_9 (accuracy, 7 %)
[OK]     linup-1_10 (accuracy, 2 %)
[OK]     Tomography_11 (accuracy, 1 %)
[OK]     PSI_Focus_12 (accuracy, 1 %)
[OK]     PSI_Focus_13 (accuracy, 8 %)
[OK]     ILL_H16_14 (accuracy, 1 %)
[OK]     Test_FocalisationMirrors_15 (accuracy, 1 %)
[OK]     ILL_D4_16 (accuracy, 2 %)
[OK]     FZJ_SANS_KWS2_AnySample_17 (accuracy, 1 %)
[OK]     FZJ_SANS_KWS2_AnySample_18 (accuracy, 3 %)
[OK]     FZJ_SANS_KWS2_AnySample_19 (accuracy, 2 %)
[OK]     FZJ_SANS_KWS2_AnySample_20 (accuracy, fair 8 %)
[OK]     Test_PSD_Detector_21 (accuracy, 1 %)
[OK]     ILL_H15_22 (accuracy, 1 %)
[OK]     Test_Fermi_23 (accuracy, fair 6 %)
[OK]     Test_Fermi_24 (accuracy, 1 %)
[OK]     Test_Fermi_25 (accuracy, fair 7 %)
[OK]     Test_Fermi_26 (accuracy, 3 %)
[OK]     Test_Fermi_27 (accuracy, 2 %)
[OK]     Test_Pol_TripleAxis_28 (accuracy, 1 %)
[OK]     Test_Collimator_Radial_29 (accuracy, 3 %)
[OK]     Test_Collimator_Radial_30 (accuracy, 3 %)
[OK]     Test_Collimator_Radial_31 (accuracy, 2 %)
[OK]     Samples_Incoherent_off_32 (accuracy, 2 %)
[OK]     ILL_H16_IN5_33 (accuracy, 4 %)
[OK]     ILL_H16_IN5_34 (accuracy, fair 8 %)
[OK]     ILL_H25_35 (accuracy, 1 %)
[OK]     ILL_H22_36 (accuracy, 1 %)
[OK]     templateTAS_38 (accuracy, 1 %)
[OK]     templateTAS_39 (accuracy, 4 %)
[OK]     linup-3_40 (accuracy, 6 %)
[OK]     Test_Pol_Bender_Vs_Guide_Curved_42 (accuracy, 2 %)
[OK]     ESS_IN5_reprate_43 (accuracy, 2 %)
[OK]     ISIS_Prisma2_44 (accuracy, 1 %)
[OK]     templateTOF_45 (accuracy, fair 8 %)
[OK]     templateTOF_46 (accuracy, 3 %)
[OK]     Test_Magnetic_Rotation_47 (accuracy, 1 %)
[OK]     Test_Pol_Set_49 (accuracy, 0 %)
[OK]     FZJ_KWS2_Lens_50 (accuracy, fair 17 %)
[OK]     Test_Selectors_51 (accuracy, 1 %)
[OK]     Test_Selectors_52 (accuracy, 2 %)
[OK]     ILL_H22_D1B_53 (accuracy, 3 %)
[OK]     linup-6_54 (accuracy, 2 %)
[OK]     ILL_H142_55 (accuracy, 1 %)
[OK]     Samples_Isotropic_Sqw_56 (accuracy, 5 %)
[OK]     ILL_H142_IN12_57 (accuracy, fair 7 %)
[OK]     ILL_H142_IN12_58 (accuracy, 21 %)
[OK]     ILL_BRISP_59 (accuracy, 4 %)
[OK]     linup-2_60 (accuracy, 2 %)
[OK]     ILL_H53_61 (accuracy, 4 %)
[OK]     Samples_vanadium_63 (accuracy, 1 %)
[OK]     Test_Pol_Guide_Vmirror_64 (accuracy, 1 %)
[OK]     ILL_D2B_65 (accuracy, 13 %)
[OK]     Test_Pol_Bender_66 (accuracy, 1 %)
[OK]     Test_Magnetic_Userdefined_67 (accuracy, 1 %)
[OK]     ILL_H24_68 (accuracy, 3 %)
[OK]     ILL_IN6_69 (accuracy, fair 11 %)
[OK]     ILL_H8_IN1_73 (accuracy, 2 %)
[OK]     ILL_H8_IN1_74 (accuracy, fair 12 %)
[OK]     linup-5_75 (accuracy, 2 %)
[OK]     templateLaue_76 (accuracy, 1 %)
[OK]     ILL_H25_IN22_77 (accuracy, fair 10 %)
[OK]     templateSANS_80 (accuracy, 6 %)
[OK]     ILL_H512_D22_81 (accuracy, 18 %)
[OK]     PSI_DMC_82 (accuracy, fair 17 %)
[OK]     Test_Magnetic_Majorana_83 (accuracy, 0 %)
[OK]     linup-4_84 (accuracy, 3 %)
[OK]     BNL_H8_85 (accuracy, fair 6 %)
[OK]     Test_Magnetic_Constant_86 (accuracy, 0 %)
[OK]     ILL_H53_D16_87 (accuracy, 4 %)
[OK]     Test_Guides_88 (accuracy, 1 %)
[OK]     Test_Guides_89 (accuracy, 1 %)
[OK]     Test_Guides_90 (accuracy, 1 %)
[OK]     Test_Guides_91 (accuracy, 1 %)
[OK]     Test_Guides_92 (accuracy, 1 %)
[OK]     Test_Guides_93 (accuracy, 1 %)
[OK]     Test_Pol_MSF_94 (accuracy, 1 %)
[OK]     ILL_IN5_95 (accuracy, 1 %)
[OK]     Test_Monochromators_96 (accuracy, 1 %)
[OK]     Test_Monochromators_97 (accuracy, 1 %)
[OK]     Test_Monochromators_98 (accuracy, 1 %)
[OK]     Test_Monochromators_99 (accuracy, 1 %)
[OK]     Test_Monochromators_100 (accuracy, 1 %)
[OK]     Test_Monochromators_101 (accuracy, 1 %)
[OK]     Test_StatisticalChopper_103 (accuracy, 0 %)
[OK]     linup-7_104 (accuracy, 1 %)
[OK]     Test_Pol_Mirror_105 (accuracy, 1 %)
[notest] Reflectometer (no test procedure)
[notest] Test_Lens (no test procedure)
[notest] SNS_analytic_test (no test procedure)
[notest] SNS_test (no test procedure)
[notest] ISIS_CRISP (no test procedure)
[notest] TestSANS (no test procedure)
[notest] Test_pol_tabled (no test procedure)
[notest] Test_SSR_SSW_Guide (no test procedure)
[notest] ESS_2001_bispectral (no test procedure)
[notest] ESS_Brilliance_2012 (no test procedure)
[notest] Test_SSR_SSW (no test procedure)
[notest] Test_Sample_nxs_diffraction (no test procedure)
[notest] Test_Sample_nxs_imaging (no test procedure)
[notest] ISIS_TS2_Brilliance (no test procedure)
[notest] ESS_Brilliance_2001 (no test procedure)
[notest] Histogrammer (no test procedure)
[notest] RITA-II (no test procedure)
[notest] template (no test procedure)
[notest] ISIS_TS1_Brilliance (no test procedure)
# Execution check:    FAILED. 5 instrument(s) did not compile/execute.
# >> Check instruments and mcstas installation.
# End Date: Mon Apr 29 00:45:49 2013